Event Title

Biocompatibility of Hydroxyapatite and Cobalt-Chrome Alloys

Location

CSU Ballroom

Start Date

10-4-2018 10:00 AM

End Date

10-4-2018 11:30 AM

Student's Major

Biological Sciences

Student's College

Science, Engineering and Technology

Mentor's Name

Michael Bentley

Mentor's Department

Biological Sciences

Mentor's College

Science, Engineering and Technology

Second Mentor's Name

Kuldeep Agarwal

Second Mentor's Department

Automotive and Manufacturing Engineering Technology

Second Mentor's College

Science, Engineering and Technology

Description

The biomaterial used in medical implantable devices must be able to sufﬕciently integrate within the biological system and remain compatible with surrounding tissue. Previously, Stainless Steel was explored. Cobalt Chrome (CC) will now be utilized due to higher biocompatibility while minimizing immune response and rejection. Hydroxyapatite (HA), a bioactive material that is a major and essential component of normal bone and teeth, is often used for coating metal implants to initiate infiltration. However, its bioactivity leads to high biodegradation when implanted alone, which can result in clinical implant failure. In the present study, our focus is on the biocompatibility of a mixture alloy of stainless steel and hydroxyapatite, fabricated by using a three-dimensional printer. To test the biocompatibility of the fabricated metal implant in vivo, one millimeter-sized metal pieces of high and low HA ratio mixture alloys were inserted on rat skulls through a small incision on the back made using a sterilized implantation surgery. After four months, the metal pieces were removed and observed under scanning electron microscopy to determine the degree of infiltrated bone and connective tissue. The surrounding connective tissues were also examined for inflammation and other tissue damages. The result showed that, the metal alloys that were fixed on the bone were encapsulated by dense connective tissue continuous with the periosteum without having any signs of inflammation or rejection. Furthermore, the connective tissue infiltrated into spaces within alloy, between and around the spheres of cobalt chrome, and formed a dense matrix of cellular and fibrous material throughout the implant. As further study, an implant using CC and HA with various particle bond strength will be implanted for better infiltration of bone growth and formation of vessel. Our findings will help improve medical device alloys for hip, femur and other implants.

This document is currently not available here.

Share

COinS
 
Apr 10th, 10:00 AM Apr 10th, 11:30 AM

Biocompatibility of Hydroxyapatite and Cobalt-Chrome Alloys

CSU Ballroom

The biomaterial used in medical implantable devices must be able to sufﬕciently integrate within the biological system and remain compatible with surrounding tissue. Previously, Stainless Steel was explored. Cobalt Chrome (CC) will now be utilized due to higher biocompatibility while minimizing immune response and rejection. Hydroxyapatite (HA), a bioactive material that is a major and essential component of normal bone and teeth, is often used for coating metal implants to initiate infiltration. However, its bioactivity leads to high biodegradation when implanted alone, which can result in clinical implant failure. In the present study, our focus is on the biocompatibility of a mixture alloy of stainless steel and hydroxyapatite, fabricated by using a three-dimensional printer. To test the biocompatibility of the fabricated metal implant in vivo, one millimeter-sized metal pieces of high and low HA ratio mixture alloys were inserted on rat skulls through a small incision on the back made using a sterilized implantation surgery. After four months, the metal pieces were removed and observed under scanning electron microscopy to determine the degree of infiltrated bone and connective tissue. The surrounding connective tissues were also examined for inflammation and other tissue damages. The result showed that, the metal alloys that were fixed on the bone were encapsulated by dense connective tissue continuous with the periosteum without having any signs of inflammation or rejection. Furthermore, the connective tissue infiltrated into spaces within alloy, between and around the spheres of cobalt chrome, and formed a dense matrix of cellular and fibrous material throughout the implant. As further study, an implant using CC and HA with various particle bond strength will be implanted for better infiltration of bone growth and formation of vessel. Our findings will help improve medical device alloys for hip, femur and other implants.

Recommended Citation

Hasan, Mehedi; Bethany Haus; and Eryn Zuiker. "Biocompatibility of Hydroxyapatite and Cobalt-Chrome Alloys." Undergraduate Research Symposium, Mankato, MN, April 10, 2018.
https://cornerstone.lib.mnsu.edu/urs/2018/poster-session-A/7